Forest Grove, OR "mystery sound" (Feb 2016): a steady 1147.6 Hz tone, looks like a pressure whistle

1 day ago 17

PROTECT YOUR DNA WITH QUANTUM TECHNOLOGY

Orgo-Life the new way to the future

  Advertising by Adpathway

Every outlet's recording has the same steady tone at 1147.6 Hz

That's a very interesting piece of spectral analysis, particularly the consistency of the 1,147.6 Hz frequency across the recordings.

I think there are two important distinctions worth exploring before ruling out electrical machinery.(I do have a electronic/electrical engineering background but havent really used it like this in a while so this took some thinking about and research, its also a bit long winded also)

1-The American electricity supply operates at 60 Hz, compared with 50 Hz in Europe (fyi European Debunkers). Conventional transformer hum is principally associated with twice the supply frequency.

The fundamental sound frequency is twice the power line operating frequency of the transformer.

Acme Electric — What causes transformer noise?

However, transformers also generate harmonics. These are whole-number multiples of the fundamental frequency, meaning a 120 Hz hum can have additional components at 240, 360, 480 Hz and upwards like 1200HZ.

But also

The noise spectrum is composed of multiple harmonics of the line frequency, 60 Hz

Transformer Technology — Quiet by Design: Understanding and Reducing Transformer Noise

The ninth and tenth harmonics of 120 Hz would be 1,080 and 1,200 Hz. Interestingly, the nineteenth multiple of 60 Hz is 1,140 Hz, just 7.6 Hz below the reported tone. Nevertheless, 1,147.6 Hz isn't an exact mains harmonic, so ordinary transformer hum remains an unlikely explanation.

I may need to think about this a bit more there is a ±0.03 Hz tolerance so the 19th harmonic of 1040 could go as high as 1040.57, @SkyAugur what was your actual lowest bound figure? Electronic motor controllers can generate other frequencies from the standard 60 Hz supply also.)

Could mechanical resonance be involved? Possibly, but resonance normally amplifies an existing excitation frequency rather than shifting a sustained mains harmonic to an unrelated frequency.

the natural response of the system will be damped out.

Penn State — Undamped Harmonic Forced Vibrations

This leaves the sustained vibration following the driving frequency. A separate resonant or nonlinear mechanism would therefore need to be demonstrated.

2- Electrical frequency versus mechanical noise? A second distinction is that ruling out direct electrical hum doesn't rule out mechanical noise from an electrically driven fan or pump.

A conventional two-pole AC motor has a synchronous speed of 3,600 RPM on America's 60 Hz supply, but induction motors run slightly slower under load.

Speed of an operating electrical motor with load is lower than the synchronous speed

Engineering ToolBox — Electrical Motors: Speed at Operating vs. Synchronous Load

The accompanying table gives approximately 3,450 RPM for a typical loaded two-pole motor.

1794625035794.png

More importantly, fans and impellers produce their own acoustic frequencies, determined by blade count and rotational speed.

Calculation: (Number of blades x fan RPM) / 60 Hz

AMCA International — Basics of Fan Noise, slide 54

For example, a hypothetical 20-blade blower running at 3,442.8 RPM would produce a blade-passing frequency of exactly 1,147.6 Hz, potentially accompanied by higher harmonics. That's remarkably close to a conventional two-pole induction motor's typical operating speed.

A fan or pump can also change pitch during startup and shutdown as its rotational speed changes. Admittedly, the reported upward chirp at cutoff would need further explanation, since a freely slowing fan would normally decrease in pitch.

So I think the absence of an exact 60 Hz relationship is useful evidence against direct electrical hum, particularly from a transformer, but it doesn't eliminate an electrically driven fan or pump.

The frequency stability, harmonics and precise startup/shutdown behaviour deserve closer examination before choosing between a rotating mechanical source and a pressure-driven whistle in my opinion.

Its tricky one, I may have over looked something and not a simple problem I think.